BAM High Voltage Power Capacitor
Fa'aoga ma Tulaga Fa'atonu:
E masani ona faʻaaogaina le eletise eletise maualuga i le AC Power system ma le 50Hz e faʻaleleia ai le malosiaga. Ole fa'atinoga e fa'atusalia ile GB 3083.2-89 《Mata'i eletise shunt capacitor》ma le IEC60871-1987.
GB/T11024-2010 National standard 《 Fa'atulagaina voltage 1kV po'o luga atu shunt capacitors mo faiga eletise AC
JB/7112-2000 Masini Alamanuia tulaga 《 Faʻapipiʻi HV Shunt Capacitor
DL/T628-1997 Alamanuia Malosiaga Fa'aeletise tulaga fa'apitoa 《Fa'apipi'i HV Shunt Capacitor Oka Manaoga Fa'ainisinia》
Tulaga Fa'aoga:
1. Altitude: itiiti ifo i le 1000m; Vevela ole ambient: -40℃ ~ +40℃.
2. Leai se vevesi faʻainisinia faʻamalosi, leai se kesi leaga ma ausa, leai se eletise, ma mea pāpā, ma pefu paʻu i le nofoaga.
3. Fa'aauau le fa'agaoioiga voltage: 1.00 Un, umi umi max, I luga o le voltage: itiiti.1 Un.
4.Stable over-current (e aofia ai le harmonics current) itiiti ifo 1.3 In.
5.With tu voltage: i le va o terminal 2.15, taimi fuaina voltage mo 10 sekone, i le va o terminals ma pusa 42kV mo 10 sekone.
uiga fa'ainisinia autu:
1. Fa'avasegaina voltage: 6.3kV, 6.6kV, 6.6/√3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, fa'amolemole fa'ailoa i le fa'atonuga pe afai e te mana'o i le isi gafatia fa'apitoa.
2. Fa'atulagaina gafatia: 33 ~ 334kvar fa'amolemole fa'ailoa i le fa'atonuga pe a e mana'o i le isi gafatia fa'apitoa.
3. Fa'apalepale gafatia: -5 ~ 15%.
4.Loss angel tangential taua: ata tifaga & papaer medium tg θ≦0.08%, ata tifaga ala tg θ≦0.05%.
5.Tagata voltage: e mafai ona gafatia AC2.15 po DC4.3 taimi fuaina voltage i le va o pales gafatia, mulimuli e uiga i 10s e aunoa ma le motusia po o moli, BIL: 6kV(30kV), 10kV(42Kv).
6. Faʻasalaga saoloto: o loʻo i ai le teteʻe i totonu, 10min pe a uma ona tipi ese le eletise, o le a faʻaitiitia le voluma i le 75V mai le √2 Un.
7.Max. O loʻo i ai nei: faʻasolosolo sologa lelei i lalo ole 1.3 taimi faʻamauina le voltage, luga o le voltage, gafatia lelei le faapalepale ma le galu malie e le mafai ona sili atu i le 1 min i le 24 itula.
8.Max.Current: tamo'e sologa lelei i lalo ole 1.3 taimi fuaina voltage, i luga o le voltage, gafatia lelei faapalepale ma harmonic galu lea e le mafai ona 1.43 taimi faatulagaina i le taimi nei.
9. Tulaga: GB/T 112024.1-2001, IEC6087:1997.
VAEGA MAFAI VAEGA MAFAI
Fa'ata'ita'iga BAM | Malosi Fa'atatau (kV) | Tulaga Fa'atatau (kVAr) | Fa'atonuga (uF) | Fa'atatau i le taimi nei I(A) |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | lua sefulu fa | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | lua sefulu fa | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | lua sefulu lua | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |